Precautions for using a check-free electric boiler

Precautions
1. Exempted inspection electric boilers shall be accompanied by "design documents required by safety technical specifications, product quality certification, safety and maintenance instructions, supervision and inspection certificate (safety performance supervision and inspection certificate)".
2. Installation, maintenance and renovation of the boiler. The unit engaged in the installation, maintenance and transformation of the boiler shall obtain the qualification certificate for the installation and maintenance of special equipment issued by the provincial quality and technical supervision bureau before it can engage in the installation, maintenance and transformation of the boiler. Before the construction, the construction unit will inform the municipality or the special equipment safety supervision and management department of the municipality directly under the jurisdiction of the construction, maintenance and transformation, and send the construction notice to the local county-level quality and technical supervision bureau for the record, and then notify the construction.
3. Acceptance of boiler installation, maintenance and renovation. After the completion of the construction, the construction unit shall report the water pressure test and installation supervision of the boiler to the Special Equipment Inspection Institute of the Quality and Technical Supervision Bureau. After passing the qualification, the Quality and Technical Supervision Bureau, the Special Equipment Inspection Institute, and the County Quality and Technical Supervision Bureau will participate in the whole experience.
4. Registration of the boiler. After the boiler is accepted, the user must fill in the "Boiler (Census) Registration Form" in accordance with the "Regulations on the Registration and Use of Special Equipment", register with the Quality and Technical Supervision Bureau, and apply for the "Registration Certificate for the Safe Use of Special Equipment". .
5. Operation of the boiler. Boiler operation must be carried out by a certified person who has passed the training and obtained the "Special Equipment Operator Certificate". The operation rules, eight systems and six records must be strictly observed during use.
6. Inspection of the boiler. The boiler shall be inspected once a year, and boilers that have not been inspected safely shall not be used. The safety accessories of the boiler are regularly inspected once a year. The pressure gauge is checked once every six months. Safety accessories that have not been inspected regularly shall not be used.
7. It is strictly forbidden to install the atmospheric boiler as a pressure boiler. It is strictly forbidden to use boilers with three safety accessories such as water level gauge, safety valve and pressure gauge.

Non-Inactivated Disposable Virus Sampling Tube

This disposable Non-Inactivated virus sampling tube is an upgrade from the Hank's solution. Additional various components, such as BSA, HEPES, amino acids, cryoprotectant, etc., are added to enhance the virus integrity. It can be used for nucleic acid extraction of virus, mvcoplasma chlamydia and ureaplasma samples and later virus isolation.
This disposable non-inactivated virus sampling tube consists of fibrous swab and culture medium.The medium contains antibiotics and antimycotics for the purpose of inhabitation of bacteria and veasts overgrowth. It helps to maintain the cellular integrity and preserve the viruses, mycoplasma, chlamydiae and ureaplasma.
When collect specimens with this disposable Non-inactivated virus sampling tube, tube can be transported to the laboratory at 2-8ºC within 2 days. If it can not be delivered to the laboratory within 48hours, it should be stored at-70ºC or below, and ensure that the collected specimens are delivered to the laboratory within 1 week. Avoid repeated freeze-thaw cycles. For best performance, complete testing within 24 hours.

Nucleic acid extraction tube,DNA virus sampling tube,Viral Transport Medium Test Tube,Non-Inactivated VTM,Non-Inactivated specimen tube

Shenzhen Uni-medica Technology Co.,Ltd , https://www.unimedicadevice.com