What is SHR?
SHR stands for Super Hair Removal which utilizes the most advanced technology of "in- motion" to carry out painfree treatment. SHR is able to output 10 shots at 1 second and make treatment movable. Combining with perfect semi-conductor cooling system, this machine brings totally pain free and comfortable treatment feeling. It is more effective than traditional IPL machine.
FP=Flyer Point
FP mode was developed by R&D Department of Sincoheren. FP outputs a series of pulses during operation in different sensitive areas, such as upper lips, hairline, and front ear etc. By using FP mode to do hair removal, the treatment is more accurate and effective, especially for thin hairs. More comfortable treatment experience on small areas will be realized.
Precipulse Technology
1. Multipulse technology makes treatment more efficient through selectively adopting different pulse width and duration on different target tissues.
2. Perfect square, balanced energy output and "in-motion" treatment will be well realized.
3. Epidermis will be maximally protected and gradual increasing of epidermis temperature is guaranteed.
4. Target tissue reaches treatment temperature rapidly so as to guarantee therapeutic result.
5. Totally comfortable treatment, no side-effect.
Â
Applications
l Hair removal
l Skin rejuvenation
l Wrinkles reduction
l Skin tightening
l Acne Lightening and eliminating
l Skin elasticity improving
l Vascular lesions removal
l Telangiectasis curing
l Freckles eliminating
l Removal of pigmentations, age spots, sun spots, etc
AdvantagesÂ
l PreciPulse, accurate energy output (deviation <5%)
l 3 treatment heads: HR; SR; VR
l 3 treatment modes, traditional IPL, FP (FlY POINTS) mode, SHR mode for different diseases
l 2000W IPL power supply system, discharge frequency 1Hz
l Strong cooling system and 100W power guarantees continuous working for one hour and a half
l Mini and delicate treatment hand Piece, easy to output
l TDK-Lambda switching power supply system
l USB reserved connector for future upgrading
Hand Pieces for different treatments:
Spot Size: HR 16*57mm, SR 8*34mm, VR 8*34mm
Â
Advantages of IPL SHR System |
Â
Â
<1>Â Â Big high-definition touch screen. Easy, safe and convenient to operateÂ
<2>Â 3 treatment heads: HR; SR; VR(optional).Â
HR is for hair removal; SRis for skin rejuvenation,eliminate Speckles, sun spot, age spot, skin pigmentation,etc. ; VR is for vascular remova, veins removal.
HR treatment head for hair removal can remove unwanted hair completely and permanently. HR is big spot, It's more convinient and faster to do treatment on large area of skin like leg and back.
<3> it is very beautiful in shape. The color of the machine is multi-optional.
<4>Â It has 3 cooling systems, which makes the treatment safe, fast, and high-effective.
Big Spot Handpiece
Spot Size: 8*34mm, Â 16*57mm free to choose according to your demand
Â
User Friendly Interface:
Â
 Â
Â
Specifications:
Â
Â
Comparison with other IPL Models supplied by Sincoheren
Â
Certifications
FDA, ISO13485, CE Approval .
Â
Â
Â
Specification of ipl shr Body Hair Removal machine |
Â
Light source |
Xenon lamp |
Spectrum |
HR 690-1200nm  SR 560-1200nm |
Pulse duration |
20-149.7ms |
Pulse Sequence |
2 or 3 Pulses |
Repetition |
≥0.5Hz |
Energy density |
20-50J/cm² |
Spot size |
16×57 mm for HR   8×34 mm for SR |
Cooling system |
Semiconductor cooling, Built-in water cooling and air cooling |
Skin cooling |
Contact skin cooling technology |
Electrical requirement |
230VAC  50Hz  1200W |
Dimension(W×D×H) |
46cm*75cm *40cm |
Net Weight |
36kg |
Â
Â
Upgraded technology |
Â
Â
Professional packing with great protection, guarantee safety for long distance transportation.
Package Size:Â 62*68*124cm, Net Weight: 43KG
Â
1. 24 hours quick response!
2. User manual, service manual, maintenance manual and DVD support!
3. 1 year free warranty and life-long service!
4. Professional engineer service and branch office in Euro, Australia and HK, quick after-sale service!
OEM/ODM Service:
1. Sincoheren has an integrated professional system for products research and development, manufacture, certificates identification, market promotion.Â
2. Completely and well organized SPDP procedure to develop products.
3. 50 people working for R&D depart.
4. Sucessfully provide OEM/ODM service to USA distributor, Germany distributor, Turkey distributor, Australia distributor and so on.
Beijing Sincoheren S&T Development co., Ltd, established in 1999, is one of the largest and the earliest professional hi-tech manufacturers of medical and aesthetic equipments. We have our own Research & Development department, factory, international sales departments, overseas distributors and after sales department.And now we have Service-Department in Australian and in Deutschland.
Â
Q: What areas can be treated with IPL Permanent Hair Removal Machine series?
A:Â IPL series remove hair from all parts of the body including the face, legs, arms, underarms, and back. It can also treat sensitive areas like the chest, nipples, and bikini line.
Q: Besides the treatment for hair removal, what other treatment can I get?
A: It's also a non-invasive light treatment that can be customized for different skin tones and aging skin conditions. The result is an exceptionally effective skin rejuvenation treatment with minimal discomfort.
Q: What do treatments feel like?
A:Â When the pulse of light is delivered, some patients experience a mild pinching or stinging sensation. No local anesthesia or pain medication is typically required, Gel is recommended to cool the skin before vascular treatments. However some patients may prefer to use a topical anesthetic when sensitive areas are treated.
Q: How many treatments will I need?
A:  Each treatment regimen is different and customised to an individual patient's needs. Most areas require 3-6 treatments. However, treatments required for optimal long-term benefits depends on multiple factors - hair thickness, the area treated and your hair's growth cycle. Interestingly, not all hairs are actively growing at the same time and actually go through three distinct phases: growth, regression, and resting.
Q:Â What happens after the treatment?
A:Â Immediately following IPL treatment, the area may appear a bit red and swollen. Three to seven days after treatment you may experience what seems to be regrowth of hair. Actually, most of these hairs are being shed as a result of your treatment and are not regrowing. Between treatments you should not wax or pluck your hair, but it is permissible to shave.
Q: Are there any restrictions on my activities after treatment?
A:Â Following the treatment, you can return to your normal activities right away, but some redness may occur. The use of sunscreen is recommended on any treated areas exposed to the sun. In addition, your physician may recommend that you use a specially formulated skin care product line or prescribe a skin care regimen especially formulated for your skin type.
Q: Are there any side effects?
A:Â The most common side effect is a slight redness or mild swelling in the treated area that disappears within a few hours.
Q: When will I see results?
A:Â Immediate results are observed by some patients. More typically, you will see results in two to four weeks and improvements will continue for several
Â

[Sample requirements]
The collected nasopharyngeal swab samples should be transported at 2°C to 8°C and sent for inspection immediately, and the sample delivery and storage time should not exceed 48 hours.
[Testing method]
1. Before sampling, mark the relevant sample information on the label of the sampling tube.
2. According to different sampling requirements, use a sampling swab to sample in the nasopharynx.
3. The specific sampling methods are as follows:
a) Nasal swab: Gently insert the swab head into the nasal palate, stay for a while and then slowly turn to exit. Wipe the other nostril with another swab, immerse the swab head in the sampling solution, and discard the tail.
b) Pharyngeal swab: Wipe bilateral pharyngeal tonsils and posterior pharyngeal wall with a swab, also immerse the swab head in the sampling solution, and discard the tail.
4. Quickly put the swab into the sampling tube.
5. Break the part of the sampling swab higher than the sampling tube, and tighten the tube cover.
6. Freshly collected clinical specimens should be transported to the laboratory within 48 hours at 2°C to 8°C.
[Explanation of test results]
After the sample is collected, the sampling solution turns slightly yellow, which will not affect the nucleic acid test result.
[Limitations of the test method]
1. For samples that are seriously contaminated due to improper storage after collection, the final test results will be affected.
2. If the sample is not stored at the specified temperature, the final test result will be affected.
Vtm Sampling Tube With Swab,Disposable Collection Tube Of Virus Samples,Hi Media Vtm Kit,Amylase Sample Collection Tube
Jilin Sinoscience Technology Co. LTD , https://www.contoryinstruments.com