Model NO.: BS-YJP040DR-A
Frequency: 50/60Hz±1Hz
Power Capacity: ≤0.5Ω
Maximum Output Power: P =110kv*36mA=4kw
Nominal Power: 100kv, 40mA, 0.1s, 4kw
Kv Adjusting Range: 40kv~110kv, Continuous Adjustment Step 1 Kv
Ma Adjusting Range: 36mA~70mA
S Adjusting Range: 0.04s~3.2s
X-ray Tube: Focus: 0.6/1.5mm; Anode Heat Capacity: 76khu
Anatomy Program: 48 Kinds of Memory Choices
Trademark: Bisen
Transport Package: Standard Carton Box for Export
Specification: 100kV, 40mA, 0.1s, 4kW
Origin: China, Guangzhou

BS-YJP040DR-A Portable 4kW Digital Medical Diagnosis High Frequency X-Ray Machine With Cheap Price
Picture:
1.2.3. Portable high frequency x-ray machine
4. Machine frame Â
5. Power synchronous box Â
6. Digital detector Â
7. Laptop
Parameters:
1.   Components:
The main components are shown in the following table and figure.
Main components | Name of components | Specification | Quantity | Remark |
DR system | Portable high frequency x-ray machine | MCX-P40-R | 1 set | Â |
Digital detector | Xmaru1210p | 1 set | Â | |
Synchronous box | YJT-3 | 1 set | Â | |
Laptop | Y470N-IFI (H) | 1 set | Â | |
DR image processing software | -- | 1 set | Â | |
Accessory equipment | Machine frame | YJF-I | 1 set | Optional components |
2.   Application:
4kW digital portable medical diagnosis high frequency X-ray machine, used for human limbs checking and diagnosing, especially in the wild places, battlefield flow, playground, pet clinic, and rescue diagnosis etc.
3.   Characteristics:
1)Â Â Â Deft and concise.
2)Â Â Â 6 periods of digital LED display.
3)Â Â Â 24 kinds of presupposed anatomy memory pattern choices.
4)Â Â Â Accuracy control method of simulation and double digital loops.
5)Â Â Â High precision control of tube voltage, tube current.
6)Â Â Â Failure self-protection, self-diagnosis.
4.   Dimension:
(1) X-ray machine head (length × width × height): 442mm × 347mm × 230mm
(2) Machine stand (length × width × height): 1060 mm × 790 mm × 2210 mm
5.   Parameters:
 Model | YJP040DR-A |
Input power |
Voltage: AC220V±22V  Frequency: 50/60Hz±1Hz      Power capacity: ≥5kVA   Inner resistance: ≤0.5Ω |
Maximum output power |
P =110kV×36mA=4kW |
Nominal power | 100kV, 40mA, 0.1s, 4kW |
Frequency | ≥40kHz |
kV adjusting range | 40kV~110kV, continuous adjustment step 1 kV |
mA adjusting range | 36mA~70mA |
mAs adjusting range | 1mAs-200mAs, shifted adjustment |
s adjusting range | 0.04s~3.2s |
X-ray tube | Focus: 0.6/1.5mm; Anode heat capacity: 76kHU |
Varian digital detector |
Limit resolution: 3.6LP/mm; A/D conversion:14bit; Pixel area:427*356mm; Pixel matrix: 3072*2560 |
Laptop |
a) Model: Lenovo Y470N-IFI(H)Â Â Â Â b) CPU: Intel Core i5-2410M(2.3GHz) c) Memory capacity: 4GBÂ d) Hard drive capacity: 750GBÂ e) Screen size: 14 inch |
Anatomy program | 48 kinds of memory choices |
X-ray machine Size | 290×260×230 mm |
Weight | 18.8kg |
Accessory | Standard: switch, cables; Option: mobile scaffold |
Machine frame |
The highest size of mobile frame is: 1060 × 790 × 2210mm The lowest size of mobile frame is: 1060×790×1240mm The net weight of mobile frame about: 23 kg |

Alice Tao
Mobile phone: +86 157 1171 4566
Tel: 020-22090206
Website: www.bisenmedical.com
Novelty Hardware Manufacturer , http://www.ywtattooneedles.com