Drinking water hygiene
Broilers should drink tap water or clean well water to drink water, try to avoid drinking river water, and use waterproof sources to infect and infect diseases.
The drinking water system is regularly cleaned and disinfected, as the water tanks and pipes are prone to bacterial growth and dirt or contaminants. This is accomplished by first draining all the drinking water system and adding chlorine-containing water (50 mg/kg). After immersing the entire system for 30 minutes, rinse the entire system for 15 minutes. This will greatly reduce the amount of contaminants, impurities, and bacteria. Drinking water should continue to add chloride to improve the hygiene conditions of drinking water. Open drinking water systems (eg sinks, Paramount drinking fountains) should be filled with enough chloride in the water pump or tank to ensure that the water supply system still contains 3 mg/kg of chloride at the furthest end. When using a nipple drinker, 1 mg/kg of chloride should be placed farthest from the water source. Drinking water should be checked once a month to ensure that there is no E. coli in the water. Drinking and Immunity
Before the immunization, the birds should be dehydrated for 2 hours to 4 hours, except during the hot season. For 1 day old - 21 day old chickens, only 10 ml - 20 ml water is needed. For chickens 21 days old or older, in principle, 40 ml. When drinking water, the correct amount of vaccine should be mixed into the water.
Closed drinking system drinking immunity. Raise the drinking system so that chickens do not come into contact. Open the end of the drinking system, put all the water in a clean place, and then pump the vaccine mixture into the system. When the mixture is seen at the end, the end is closed, ensuring that the vaccine reaches any drinking fountain in the system. At this point, the drinking system can be lowered to allow the birds to drink.
Open drinking system drinking immunity. Rinse and scrub the water dispenser with clean, disinfectant-free water while providing plenty of room for drinking water. At least 2/3 of the flock can drink at the same time. Raise the drinking fountain first, and wait for the fountain to appear when all the fountains are mixed. After the chickens had finished drinking the vaccine mixture, they opened the regular water supply system.
Water control program
Drink water for the first time: 1 hour to 2 hours after feeding in the morning. Specific schedule: Shewen temperature above 28°C, no water control; 21°C-28°C, normal drinking water; 18°C-21°C, water supply after finished material 90 minutes; 14°C-17°C, 85 minutes; 10°C-13°C , 80 minutes; 6°C-9°C, 75 minutes; 2°C-5°C, 70 minutes; 1°C-2°C, 65 minutes.
The second drinking (around 11am): Sherwin 17°C-28°C, water for 30 minutes; 8°C-16°C, 25 minutes; 2°C-7°C, 20 minutes.
The third drinking (in the afternoon): Sherwin 17 °C -28 °C, water for 30 minutes; 8 °C -16 °C, 25 minutes: 2 °C -7 °C, 20 minutes.
Drinking for the fourth time (starting at half hour before turning off the lights at night): Sherwin 17°C-28°C, water supply for 30 minutes; 8°C-16°C, 25 minutes; -2°C-7°C, 20 minutes; below -2°C, no Water supply.
Laser distance measure is a very convenient tool for various types of applications in industries, construction and house decoration. Laser distance meter is a very useful device which gives accurate measurement of distance, area and volume especially in large areas such as rooms, apartments, buildings, real estates, factories, warehouses, infrastructures, gardens, roads, and many other applications requiring accurate results for distance , area and volume measurement.
Trade your heavy tape measure for laser
rangefinder, which let you simply take measurements with one hand. No matter
your job, the laser rangefinder will help you measure much farther, with
greater accuracy and in more situations, saving you money and time.
Specification:
Product Model: |
JX40 |
Accuracy: |
±1.5mm (0.06 inch) |
Measuring Unit: |
metre/inch/feet |
Measuring Range: |
0.03~40m (0.01 to 131 ft) |
Measuring Time: |
0.1~4 seconds |
Laser Class: |
Class II |
Laser Type: |
635nm, <1mW |
Waterproof & Dustproof : |
IP54 |
Auto Laser Off: |
60 seconds |
Automatic Power-off: |
480 seconds(8 minutes) |
Lighting: |
white LED |
Datum Option: |
Can choose Front edge or end piece edge as datum |
Battery Status: |
Y |
Signal Strength Display: |
Y |
LCD display: |
2 inch large screen |
Display illumination and multi-line display: |
Max 2 displays |
Data Memory: |
Y (allow 20 values) |
Backlight display: |
Y |
Continuous Measurement: |
Y |
Min/max Measurement: |
Y |
Addition/Subtraction(Distance/Area/Volume): |
Y |
Area/Volume/Pythagoras Measurement: |
Y |
Battery Type: |
AAA alkaline battery(2*1.5v ) |
Weight: |
about 80g |
Dimensions(L*W*H): |
4*2*11.5cm |
Auto correction and error report technology: |
Y |
Operating Temperature: |
0-40 ℃(32-104 ℉ ) |
Storage Temperature: |
-20~60 ℃ (-4~140 ℉) |
Laser Distance Meter,Laser Distance Measure,Laser Rangefinder,Laser Distance Gauge
Chengdu JRT Meter Technology Co., Ltd , https://www.rangesensors.com