Yste161V Fully Automatic Vet Clinical Chemistry Analyzer

Model NO.: YSTE161V
Wavelength: 340-810nm
Light Source: Halogen Lamp
Absorbance Resolution: 0.0001A
Trademark: YSENMED
Transport Package: Wooden Case
Origin: Guangzhou
Model NO.: YSTE161V
Wavelength: 340-810nm
Light Source: Halogen Lamp
Absorbance Resolution: 0.0001A
Trademark: YSENMED
Transport Package: Wooden Case
Origin: Guangzhou
YSTE161V Fully Automatic Vet Clinical Chemistry Analyzer

Yste161V Fully Automatic Vet Clinical Chemistry Analyzer

Model: YSTE161V

Application:
Biochemistry Analyzer is designed for vet clinic or laboratory to measure the quantity of chemical or biochemical components in animal serum, urine and other liquid sample, used to test liver function, kidney function, cardiac markers, blood sugar, blood lipid, etc.

 
Technical Specifications:
 Analytical System  Fully automatic, Random Access
 Method  End point, Rate, Fixed time, Immunoturbidimetric, 1-2 regent, 

 Multistandard, reagent/serum blank, etc
 Assay Item  30 assay
 Throughput 1 Reagent  160 tests/hr
2 Reagent  100 tests/hr
 Test Menu  T.BILI, r-GT/GGT, CHO, Ca, APOB-1/B, CHE
 D.BILI, ALP/AKP, TG, CL, APOB, CREA
 TP, UREA, CK, P, CK-MB, Mg
 ALB, CREA, LDH, C, ASO, AFU
 Lactic Acid, ALT/GPT, UA, α-HBDH, CO2, FMN
 LP(a), AST/GOT, GLU, AMY, LDL-C, HDL-C
 CHE, LA, TBA, ADA, HS-CRP, PA
 Fe, Cu, Zn, C3, C4, IgG
 IgM, IgA and drug, toxicity,etc.
 Sample Position  30
 Including standard, control and STAT; either serum cup or 

 primary tube available
 Sample Volume  1~100ul, 0.1ul/step
 Reagent Position  40
 Reagent Volume  R1: 1~400ul, 0.1ul/step, R2: 1~400ul, 0.1ul/step
 Reagent/Sample Probe  With liquid level sensor, collision sensor, Teflon coating and 

 automatic washing station
 Reaction Time  0~999 seconds
 Cuvette  High quality uv-transmitted plastic cuvette.
 Cuvette Washing  5 channels automatic washing system for reaction cuvettes
 Probe and Mixer   

 Washing
 Independent washing station for each sample/reagent probe
 and mixer
 Alarm  Automatic alarm for malfunction (eg: collision, reagent/sample
 insufficiency, full waste container, etc)
 Calibration  Linear, Non-linear, Multi standard, K factor
 Sample Dilution/Retest  Sample can be diluted and retested if results are out of range  

 or sample is insufficient. Also with calibrator auto diluting 

 function
 Wavelength  340-810nm
 Light Source 
 
 Halogen lamp
 Absorbance Resolution  0.0001A
 Absorbance Accuracy  ±0.0003A(0-2.5A)
 Repeatability  ±2%
 Quality Control  Levy jennings quality control program at 3 levels
 Barcode  Optional
 Printer  Multiple report formats available
 System  Windows XP; Windows 7
 Power Supply  220V or 110V, 50~60Hz
 Dimension  65×53×52(cm)
 Weight  45kg


Features:
Random access fully automatic biochemistry analyzer
New concept and more friendly software
Automatic washing station for both sample and reagent probe
Liquid level detection and collision protection for both sample and reagent probe
Reliable cooling system for reagent chamber
Powerful reaction cuvette washing system barcode scanner (optional)
Lower waste and pro-environment

Structure:
1. Optical System
Light source: Halogen-tungsten lamp, 2000hours working life about
Wavelength: 340nm-810nm
Linear range:0~3ABS

2. Sample System
a) Sample tray: 30 sample position, available to use serum cup or blood tube
b) Sample volume:1~100ul, programmed by 0.1ul step
c) Sample probe: Liquid level detection and collision protection automatically
d) Probe cleaning: automatic washing both inside and outside, Carryover<0.1%
e) Automatic sample dilution

3. Reagent System
a) Reagent tray: 40 positions for single &dual Reagents.
b) Refrigeration: Refrigerated reagent
c) Compartment 24h Cooling system maintaining temperature 2~8°C
d) Reagent volume:1~400ul, programmed by 0.1ul step
e) Reagent probe: Liquid level detection and collision protection automatically
f) Pre-heating function.
g) Real-time monitoring of reagent volume and auto alarm
h) Probe cleaning: automatic washing both inside and outside, Carry over<0.1%

4. Reaction System
a) Reaction tray: 60 reaction cuvettes, High quality UV-transmitted plastic cuvettes adopt
b) Back-Dividing-Light technology
c) Min Reaction volume: 200ul
d) Reaction Temperature:37°C+0.1°C
e) Mixing system: Independent mixing probe
f) Automatic washing cuvettes

5. Washing System
a) Automatic cleaning Sample/mixer probe
b) Five channels washing station for each cuvette
c) Automatic record and deduct cuvette blank value

6. Operation Unit
Operation system: Windows XP or WIN 7
Interface: RS-232

7. Working Conditions
a) Power Supply: 220V±10%, 50/60HZ; 110V (optional)
b) Power consumption: ≤1200VA
c) Temperature:15~30°C
d) Humidity: ≤85%
e) Water consumption: 4L/h

Yste161V Fully Automatic Vet Clinical Chemistry Analyzer

Yste161V Fully Automatic Vet Clinical Chemistry Analyzer
Yste161V Fully Automatic Vet Clinical Chemistry Analyzer
Yste161V Fully Automatic Vet Clinical Chemistry Analyzer YSTE161V Fully Automatic Vet Clinical Chemistry Analyzer

Yste161V Fully Automatic Vet Clinical Chemistry Analyzer

Model: YSTE161V

Application:
Biochemistry Analyzer is designed for vet clinic or laboratory to measure the quantity of chemical or biochemical components in animal serum, urine and other liquid sample, used to test liver function, kidney function, cardiac markers, blood sugar, blood lipid, etc.

 
Technical Specifications:
 Analytical System  Fully automatic, Random Access
 Method  End point, Rate, Fixed time, Immunoturbidimetric, 1-2 regent, 

 Multistandard, reagent/serum blank, etc
 Assay Item  30 assay
 Throughput 1 Reagent  160 tests/hr
2 Reagent  100 tests/hr
 Test Menu  T.BILI, r-GT/GGT, CHO, Ca, APOB-1/B, CHE
 D.BILI, ALP/AKP, TG, CL, APOB, CREA
 TP, UREA, CK, P, CK-MB, Mg
 ALB, CREA, LDH, C, ASO, AFU
 Lactic Acid, ALT/GPT, UA, α-HBDH, CO2, FMN
 LP(a), AST/GOT, GLU, AMY, LDL-C, HDL-C
 CHE, LA, TBA, ADA, HS-CRP, PA
 Fe, Cu, Zn, C3, C4, IgG
 IgM, IgA and drug, toxicity,etc.
 Sample Position  30
 Including standard, control and STAT; either serum cup or 

 primary tube available
 Sample Volume  1~100ul, 0.1ul/step
 Reagent Position  40
 Reagent Volume  R1: 1~400ul, 0.1ul/step, R2: 1~400ul, 0.1ul/step
 Reagent/Sample Probe  With liquid level sensor, collision sensor, Teflon coating and 

 automatic washing station
 Reaction Time  0~999 seconds
 Cuvette  High quality uv-transmitted plastic cuvette.
 Cuvette Washing  5 channels automatic washing system for reaction cuvettes
 Probe and Mixer   

 Washing
 Independent washing station for each sample/reagent probe
 and mixer
 Alarm  Automatic alarm for malfunction (eg: collision, reagent/sample
 insufficiency, full waste container, etc)
 Calibration  Linear, Non-linear, Multi standard, K factor
 Sample Dilution/Retest  Sample can be diluted and retested if results are out of range  

 or sample is insufficient. Also with calibrator auto diluting 

 function
 Wavelength  340-810nm
 Light Source 
 
 Halogen lamp
 Absorbance Resolution  0.0001A
 Absorbance Accuracy  ±0.0003A(0-2.5A)
 Repeatability  ±2%
 Quality Control  Levy jennings quality control program at 3 levels
 Barcode  Optional
 Printer  Multiple report formats available
 System  Windows XP; Windows 7
 Power Supply  220V or 110V, 50~60Hz
 Dimension  65×53×52(cm)
 Weight  45kg


Features:
Random access fully automatic biochemistry analyzer
New concept and more friendly software
Automatic washing station for both sample and reagent probe
Liquid level detection and collision protection for both sample and reagent probe
Reliable cooling system for reagent chamber
Powerful reaction cuvette washing system barcode scanner (optional)
Lower waste and pro-environment

Structure:
1. Optical System
Light source: Halogen-tungsten lamp, 2000hours working life about
Wavelength: 340nm-810nm
Linear range:0~3ABS

2. Sample System
a) Sample tray: 30 sample position, available to use serum cup or blood tube
b) Sample volume:1~100ul, programmed by 0.1ul step
c) Sample probe: Liquid level detection and collision protection automatically
d) Probe cleaning: automatic washing both inside and outside, Carryover<0.1%
e) Automatic sample dilution

3. Reagent System
a) Reagent tray: 40 positions for single &dual Reagents.
b) Refrigeration: Refrigerated reagent
c) Compartment 24h Cooling system maintaining temperature 2~8°C
d) Reagent volume:1~400ul, programmed by 0.1ul step
e) Reagent probe: Liquid level detection and collision protection automatically
f) Pre-heating function.
g) Real-time monitoring of reagent volume and auto alarm
h) Probe cleaning: automatic washing both inside and outside, Carry over<0.1%

4. Reaction System
a) Reaction tray: 60 reaction cuvettes, High quality UV-transmitted plastic cuvettes adopt
b) Back-Dividing-Light technology
c) Min Reaction volume: 200ul
d) Reaction Temperature:37°C+0.1°C
e) Mixing system: Independent mixing probe
f) Automatic washing cuvettes

5. Washing System
a) Automatic cleaning Sample/mixer probe
b) Five channels washing station for each cuvette
c) Automatic record and deduct cuvette blank value

6. Operation Unit
Operation system: Windows XP or WIN 7
Interface: RS-232

7. Working Conditions
a) Power Supply: 220V±10%, 50/60HZ; 110V (optional)
b) Power consumption: ≤1200VA
c) Temperature:15~30°C
d) Humidity: ≤85%
e) Water consumption: 4L/h

Yste161V Fully Automatic Vet Clinical Chemistry Analyzer

Yste161V Fully Automatic Vet Clinical Chemistry Analyzer
Yste161V Fully Automatic Vet Clinical Chemistry Analyzer
Yste161V Fully Automatic Vet Clinical Chemistry Analyzer

Other Dish Seasoning

Delicious Noodle Seasoning,Salty Noodle Seasoning,Blended Noodle Seasoning

Hot Pot Seasoning Co., Ltd. , http://www.nsseasoning.com