Model NO.: BR108
Machine Power: 150W
Cavitaton Power: 50W
AC220/AC11010V 50/60Hz: Voltage
RF Power: 1MHz/5MHz
Diode Lights Max Power: 100mw
35k-40kHz: Cavitation Head
Hexpolar RF: 5MHz
Trademark: BEIR
Transport Package: Aluminum Case
Specification: 50cm*48cm*36cm
Origin: Guangzhou
HS Code: 90189090
Model NO.: BR108
Machine Power: 150W
Cavitaton Power: 50W
AC220/AC11010V 50/60Hz: Voltage
RF Power: 1MHz/5MHz
Diode Lights Max Power: 100mw
35k-40kHz: Cavitation Head
Hexpolar RF: 5MHz
Trademark: BEIR
Transport Package: Aluminum Case
Specification: 50cm*48cm*36cm
Origin: Guangzhou
HS Code: 90189090
Instruction
Developed by Multi-Polar RF Technology which is an innovative system maximizing all the benefits of RF technology.
Rejuvenize Face: Is a new and revolutionary system of skin rejuvenation without surgery, ana esthesia and post-operative treatment.
Rejuvenize Body: Contours, shapes and slims the body by improving cellulite and reducing circumference in as few as 3 treatment sessions. It is the fastest and safest RF system on the market effective for treating all skin types. Offers a non-surgical, non-invasive and painless treatment with no downtime for Skin Tightening & Body Contouring Treatments
Cautions for Using 40kHz Cavitation Head
1. Applied enough gel on skin need treated.
2. Do not stay unmoved on any part of your body, do not stay on bones.
3. The treatment should be within 30 minutes.
4. There will be ultrasonic only when you step on the service brake
5. Not allowed to be placed under the state of no-load to avoid the damage caused by high heat.
6. Total time for daily while using 40K cavitation explode work head.
Do 40K work head can be used on fresh part of the body, Do not use for facial. If the skin is sensitive
Or becomes unhealthy, the strength of the power should be adjusted down.
Features
Ø Mono Polar RF for body and facial
Ø Bipolar RF for for lip lines and eyebrow removal;
Ø Tripolar for Body
Ø Hexpolar with diode laser for body
Ø 40kHz Cavitation for Body Cellulite removal
Ø Facial reshape handle piece professional design for face lift and slimming;
Ø 8 inch touch screen with English and Spanish two Languages
Ø CE approved;
Ø Painless treatment focus RF energy at the correct position, compared to other radio frequency technology. Uses low energy and high frequency, safe and effective
Ø Aim at the skin surface and deep location, using a complex method to control the different currents and energy, direct access to the different skin layers, the effect is visible
Ø Selectively targeting fatty tissue, to avoid heating other fat, to achieve the fastest treatment effect
Technology Parameters
RF frequency | 5MHz |
RF level | 1-30J/cm2 |
Cavitation frequency | 40kHz |
Cavitation Power | 50W/cm2 (max) |
Power of machine | 150W |
Touch screen | 8 inch screen |
Diode laser lights | 650NM-660nm |
Diode laser power | 100MW Max |
Voltage | 220V /50Hz; AC110V/60Hz |
NW. /GW | 7KGS/13KGS |
Packaging size | 50cm*48cm*36cm |
Forbidden group
1. People with heart disease or high blood pressure, or Configured cardiac pacemaker.
2. Patients with acute inflammation, asthma, deep vein Thrombosis, thyratrons, cancer.
3. People with hemorrhagic disease, trauma or who is Bleeding.
4. Pregnant women
5. Medical Plastic parts, or parts with artificial in filling inside.
6. People with metal inside the body(include metallic tooth)
7. Patient with skin inflammation or with edema.
8. People with an abnormal immune system.
9. Numb or insensitive to heat.
Accessories list
1. Mainframe
2. Power supply line
3. User manual
4. Mono-polar RF handle piece
5. Bipolar RF handle piece
6. Tripolar RF handle piece
7. Hex Polar RF diode laser handle piece
8. 40kHz cavitation handle piece
9. Accessory Frame
10. Hexagonal Screws
11. Hexagon Wrench
Instruction
Developed by Multi-Polar RF Technology which is an innovative system maximizing all the benefits of RF technology.
Rejuvenize Face: Is a new and revolutionary system of skin rejuvenation without surgery, ana esthesia and post-operative treatment.
Rejuvenize Body: Contours, shapes and slims the body by improving cellulite and reducing circumference in as few as 3 treatment sessions. It is the fastest and safest RF system on the market effective for treating all skin types. Offers a non-surgical, non-invasive and painless treatment with no downtime for Skin Tightening & Body Contouring Treatments
Cautions for Using 40kHz Cavitation Head
1. Applied enough gel on skin need treated.
2. Do not stay unmoved on any part of your body, do not stay on bones.
3. The treatment should be within 30 minutes.
4. There will be ultrasonic only when you step on the service brake
5. Not allowed to be placed under the state of no-load to avoid the damage caused by high heat.
6. Total time for daily while using 40K cavitation explode work head.
Do 40K work head can be used on fresh part of the body, Do not use for facial. If the skin is sensitive
Or becomes unhealthy, the strength of the power should be adjusted down.
Features
Ø Mono Polar RF for body and facial
Ø Bipolar RF for for lip lines and eyebrow removal;
Ø Tripolar for Body
Ø Hexpolar with diode laser for body
Ø 40kHz Cavitation for Body Cellulite removal
Ø Facial reshape handle piece professional design for face lift and slimming;
Ø 8 inch touch screen with English and Spanish two Languages
Ø CE approved;
Ø Painless treatment focus RF energy at the correct position, compared to other radio frequency technology. Uses low energy and high frequency, safe and effective
Ø Aim at the skin surface and deep location, using a complex method to control the different currents and energy, direct access to the different skin layers, the effect is visible
Ø Selectively targeting fatty tissue, to avoid heating other fat, to achieve the fastest treatment effect
Technology Parameters
RF frequency | 5MHz |
RF level | 1-30J/cm2 |
Cavitation frequency | 40kHz |
Cavitation Power | 50W/cm2 (max) |
Power of machine | 150W |
Touch screen | 8 inch screen |
Diode laser lights | 650NM-660nm |
Diode laser power | 100MW Max |
Voltage | 220V /50Hz; AC110V/60Hz |
NW. /GW | 7KGS/13KGS |
Packaging size | 50cm*48cm*36cm |
Forbidden group
1. People with heart disease or high blood pressure, or Configured cardiac pacemaker.
2. Patients with acute inflammation, asthma, deep vein Thrombosis, thyratrons, cancer.
3. People with hemorrhagic disease, trauma or who is Bleeding.
4. Pregnant women
5. Medical Plastic parts, or parts with artificial in filling inside.
6. People with metal inside the body(include metallic tooth)
7. Patient with skin inflammation or with edema.
8. People with an abnormal immune system.
9. Numb or insensitive to heat.
Accessories list
1. Mainframe
2. Power supply line
3. User manual
4. Mono-polar RF handle piece
5. Bipolar RF handle piece
6. Tripolar RF handle piece
7. Hex Polar RF diode laser handle piece
8. 40kHz cavitation handle piece
9. Accessory Frame
10. Hexagonal Screws
11. Hexagon Wrench
Auto Destroy Syringe,Auto Disable Syringe,Disposable Syringe
Dental Equipment Co., Ltd. , http://www.sofine-dental.com